80 research outputs found

    Market Manipulation in Stock and Power Markets: A Study of Indicator-Based Monitoring and Regulatory Challenges

    Get PDF
    In recent years, algorithmic-based market manipulation in stock and power markets has considerably increased, and it is difficult to identify all such manipulation cases. This causes serious challenges for market regulators. This work highlights and lists various aspects of the monitoring of stock and power markets, using as test cases the regulatory agencies and regulatory policies in diverse regions, including Hong Kong, the United Kingdom, the United States and the European Union. Reported cases of market manipulations in the regions are examined. In order to help establish a relevant digital regulatory system, this work reviews and categorizes the indicators used to monitor the stock and power markets, and provides an in-depth analysis of the relationship between the indicators and market manipulation. This study specifically compiles a set of 10 indicators for detecting manipulation in the stock market, utilizing the perspectives of return rate, liquidity, volatility, market sentiment, closing price and firm governance. Additionally, 15 indicators are identified for detecting manipulation in the power market, utilizing the perspectives of market power (also known as pricing power or market structure), market conduct and market performance. Finally, the study elaborates on the current challenges in the regulation of stock and power markets in terms of parameter performance, data availability and technical requirements.publishedVersio

    Energy efficiency and district heating to reduce future power shortage. Potential scenarios for Norwegian building mass towards 2050

    Get PDF
    Energy efficiency, district heating and heat pumps for reduced power consumption The Norwegian power system is facing enormous challenges in the transition to a fossil-free society. The on-going electrification of transport and industry, together with establishment of new power-intensive industries, calls for rapid and extensive increase in both production of renewable electricity and the transmission grid capacity. This increase could partly be avoided through energy efficiency measures, heat pump adoption, and the use of alternative energy carriers for heating. Reduced energy delivered to buildings together with increased use of district heating have a great potential to reduce Norwegian electricity demand, and at the same time contribute to increased energy system flexibility when the grid is under the highest load. The aim of this study was to quantify the potential for increased use of district heating and heat pumps on reducing buildings’ future electricity demand in Norway. The future energy demand of the Norwegian building stock, divided into three different groups with regards to population density, was first modelled in different scenarios with respect to energy efficiency and potential access to district heating network. The outcome was then applied in an energy system model to account for different energy sources and the flexibility available in the production of district heating. The study shows that increased use of district heating reduces buildings’ electricity consumption, and in particular the buildings’ peak power demand. Comparing to 2020 level, continuing with business-as-usual will lead to 3% increase in buildings’ electricity demand by 2030, and +7% by 2050. The corresponding increase in buildings’ peak power demand is +2% by 2030 and +5% by 2050. Maximizing the use of district heating without ambitious energy efficiency standards will allow the buildings’ electricity demand to remain at the 2020 level, while buildings’ peak power demand could be reduced with -1% by 2030 and -5% by 2050. A net reduction in both total electricity and peak power demand in buildings is achieved only when maximal use of district heating is combined with ambitious energy efficiency standards and maximising the use of heat pumps in rural areas where district heating is not feasible. This scenario allowed a reduction of -12% in buildings’ electricity demand by 2030 and -26% by 2050, compared to 2020 levels. The buildings’ peak power demand could be reduced with -17% by 2030 and -35% by 2050. The results are of utmost importance for all stakeholders involved in the development of the energy system in Norway, at local and national level. Cold periods in the winter, and the inefficient use of electricity for heating, are the driving force for investments in the power system. Massive extension in the power production and transmission capacity can be partially avoided with strong emphasis on buildings’ energy efficiency, together with the use of district heating in urban areas and heat pumps in rural areas. This can reduce the total system costs for energy production and spare the natural environment for unnecessary further intervention.publishedVersio

    Stochastic load profile generator for residential EV charging

    Get PDF
    Electric vehicle (EV) charging loads have an impact on the power grid, but also represent a potential for energy flexibility. There is a need for EV data to evaluate effects on the power grid and optimal EV charging strategies. A stochastic bottom-up model is developed for residential EV charging, taking outdoor temperatures into account. The model input is based on real-world data from residential charging in Norway. The load profile generator provides hourly load profiles for any number and combination of small and large EVs, assuming immediate charging after plug-in. It is found that the model generates realistic load profiles for residential EV charging, reflecting today’s charging patterns. Data generated can be used for load and flexibility simulations for residential EV charging.publishedVersio

    Development and testing of load flexibility KPIs in the ZEN definition

    Get PDF
    This paper discusses the flexibility KPIs proposed in the context of the Zero Emission Neighborhood (ZEN) definition for characterizing how a building or neighborhood exchanges energy with the surrounding energy system and presents preliminary results of testing them on single, archetype buildings. The KPIs are calculated as the deviation of a flexible load from a baseline, typical load. The results depend on the flexibility sources activated, as well as the flexibility drivers and flexibility goals deployed for the activation. It is shown how the mechanism of flexibility works and how the KPIs can be graphically represented, with emphasis on space heating. Numeric values of the KPIs are given in ranges, given their intrinsic case to case variability and the limited experience so far accumulated with testing them. This stated, it is shown that activating flexibility can bring reductions in ΔCost (in the range of 0% to 20%), in ΔEnergy Stress and ΔPeak power (in the range 20% to 50%) even if this is accompanied by a modest increase in ΔEnergy (in the range 0% to +5%) due to some energy losses.publishedVersio

    Integrating Thermal-Electric Flexibility in Smart Buildings using Grey-Box modelling in a MILP tool

    Get PDF
    In a smart grid setting, building managers are encouraged to adapt their energy operations to real-time market and weather conditions. However, most literature assume stationary temperature set points for heating and cooling. In this work, we propose a grey-box model to investigate how the energy flexibility of the thermal mass of the building may impact its energy flexibility potential as well as the investment decisions of the energy system within a building, by using an already developed investment decision tool, BUILDing’s OPTimal operation and energy design model (BUILDopt) (Lindberg et al. (2016)). As BUILDopt is a Mixed Integer Programming (MIP/MILP) tool, the flexibility models must be linear as well. We evaluate the energy flexibility potential, here called comfort flexibility, for use cases reflecting different heating systems (electric panel ovens vs. ground source heat pump) and operation (flexible vs. non-flexible). The case study of an Office building is performed, which considers electric specific demand, domestic hot water demand and space heating demand. Real historical data for weather and energy prices from Oslo are used, including grid tariffs related energy and monthly peak power. Most of the savings are obtained through peak load reduction, which can reach up to 13-16%. These and the savings from shifting demand away from peak prices lead to total savings of around 2%. Yet, these actions do not require additional investment in heat supply or storage components, nor in building renovations: only system measurement and control components are needed.publishedVersio

    Market Manipulation in Stock and Power Markets: A Study of Indicator-Based Monitoring and Regulatory Challenges

    Get PDF
    In recent years, algorithmic-based market manipulation in stock and power markets has considerably increased, and it is difficult to identify all such manipulation cases. This causes serious challenges for market regulators. This work highlights and lists various aspects of the monitoring of stock and power markets, using as test cases the regulatory agencies and regulatory policies in diverse regions, including Hong Kong, the United Kingdom, the United States and the European Union. Reported cases of market manipulations in the regions are examined. In order to help establish a relevant digital regulatory system, this work reviews and categorizes the indicators used to monitor the stock and power markets, and provides an in-depth analysis of the relationship between the indicators and market manipulation. This study specifically compiles a set of 10 indicators for detecting manipulation in the stock market, utilizing the perspectives of return rate, liquidity, volatility, market sentiment, closing price and firm governance. Additionally, 15 indicators are identified for detecting manipulation in the power market, utilizing the perspectives of market power (also known as pricing power or market structure), market conduct and market performance. Finally, the study elaborates on the current challenges in the regulation of stock and power markets in terms of parameter performance, data availability and technical requirements

    YDALIR. Testing av alle ZEN nøkkelindikatorer i en ZEN-pilot

    Get PDF
    Testing av alle ZEN nøkkelindikatorer på Ydalir. Denne rapporten tester ut alle ZEN nøkkelindikatorene i ZEN-pilotområdet Ydalir. Resultatene skal brukes i videreutvikling og verifisering av ZEN-definisjonen og vil gi nyttige innspill til utforming av en ZEN prosessveileder. Resultatene gir forslag til hvilken rekkefølge ZEN nøkkelindikatorene kan benyttes, og viser hvor viktig det er å ta hensyn til tidshorisonten i et ZEN-prosjekt, særlig når man tar i betraktning at et ZEN-område bygges ut i faser over flere år. Resultatene gir også forslag til hvordan man kan velge referanseprosjekt og sette referanseverdier. Videre indikerer resultatene hvem som kan bruke og evaluere de ulike ZEN nøkkelindikatorene. Dette arbeidet vil bidra til videreutvikling og forankring av en norsk definisjon på et nullutslippsområde. Resultatene skal brukes i revisjon av ZEN definisjonsveilederen og til fastsettelse av referanseverdier for noen av ZEN nøkkelindikatorene. ZEN-partnere som har bidratt til arbeidet, inkluderer blant annet Elverum kommune, Elverum Tomteselskap, og Multiconsult. Oppsummerende kan vi si at rapporten prøver ut, tar i bruk og verifiserer ZEN-definisjonen og ZEN KPI. Resultatene skal brukes i videre utforming av ZEN definisjonsrapport, ZEN definisjonsveileder, ZEN KPI-verktøyet og ZEN prosessveileder.publishedVersio

    Geology of the Nevado Coropuna volcanic complex

    Get PDF
    The Nevado Coropuna volcanic complex (NCVC), located in the northernmost CAVZ (15°3’ S, 72º39’ W), includes several edifices, aligned WNW-ESE above Neogene ignimbrites. Adjacent composite volcanoes include the Late Pliocene, eroded Sunjillpa to the WNW and the glacially eroded, 0.6-0.25 Ma-old Cunciacha to the ESE. Located on the west flank of the Western Cordillera, the asymmetric volcanic complex shows stubby lava flows overlying the NE, 4500 m-high plateau, contrasting with long, inverted lava flows and debris-avalanche deposits filling deep valleys draining the steep SW flanks. The central, highest NCVC is a cluster of five, aligned lava domes reaching 6160 and 6330 masl. The dome cluster and its voluminous lava flows overlie an old stratovolcano with inverted lava flows dated at 1.02 Ma. The 0.4 Ma-old base of dome cluster is overlain by lower lava flows c. 270 - 254 ka, middle lava flows c. 118 - 108 ka, and the uppermost lava domes 70 – 60 ka. A high-spatial resolution DEM shows six vents on the domes and one collapse scar open to the south. NCVC has grown atop a caldera as shown by AMS data collected on Early Quaternary ignimbrites dipping away west, south and east of NCVC, and by abnormal contacts with both adjacent volcanoes to the WNW and the ESE. All lavas show two major compositional fields of high-K andesites and dacites (SiO2 57-67%wt). Harker diagrams and trace elements suggest AFC magmatic processes. Although CNVC tephra and PDC deposits represent a small volume, we observed Late Glacial Plinian fallout are scattered and Holocene ashfall layers are associated with three lava flows, the youngest being 1700 to 2400 yr old. The Nevado Coropuna ice cap c. 44.1 km2 is arguably the largest in the world tropical belt

    Energisparepotensialet i bygg fram mot 2030 og 2050 – Hva koster det å halvere energibruken I bygningsmassen?

    Get PDF
    I Energikommisjonens rapport "Mer av alt – raskere" beskrives et økt behov for fornybar energi til elektrifisering av transport og ny industri for å nå klimamålene, og et ambisiøst mål om energi-effektivisering i byggsektoren i størrelsesorden 15–20 TWh innen 2030. EU har ambisiøse mål for klimakutt og energieffektivisering, og bruker "Energy Efficiency First" som gjennomgående prinsipp i utformingen av direktiver. Flere virkemidler er rettet mot bygningssegmentet for å bidra til å redusere energibruken de neste årene. For å nå målet om 55 % reduksjon av utslippene innen 2030, har Europakommisjonen anslått at klimagassutslippene fra bygninger må kuttes med 60 %, sluttbruk av energi i bygg må kuttes med 14 % innen 2030, i forhold til 2015-nivå. Disse målsettingene er i tråd med det vi foreslår i denne rapporten. Det er et betydelig potensial for energieffektivisering i bygningsmassen, men dette potensialet vil ikke utløses "av seg selv". I denne studien bruker vi RE-BUILDS-modellen til å estimere potensialet for energieffektivisering i den norske bygningsmassen mot 2050. Vi ser på to scenarioer, der Baseline scenario antar at videre utvikling fortsatt følger dagens trender for energinivå på nye og rehabiliterte bygg og bruk av ulike oppvarmingsteknologier i de forskjellige segmentene av bygningsmassen. Ultra grønn-scenarioet ser på hva som er realistisk potensial for energieffektivisering, med svært ambisiøs oppgradering av energinivå ved nybygg og rehabilitering, omlegging til den mest energieffektive oppvarmingsteknologien og bruk av solceller på bygg. Energibehov i de ulike segmentene av bygnings-massen er beregnet ved hjelp av PROFet-verktøyet, en aggregert, klimaavhengig lastprofilmodell som lager lastprofiler for energibehov for 11 ulike bygningskategorier og tre energinivåer. Baseline scenario viser at en fortsettelse av dagens trender fører til at samlet tilført energi øker med 2 TWh fra 2020 til 2030 og med 4 TWh fra 2020 til 2050. Økningen skyldes at bygningsmassen vokser, og at bedringen i energinivå ikke fullt ut klarer å kompensere for denne økningen. I dette scenarioet er omfanget av solstrøm neglisjerbart, og tilført energi er derfor lik levert energi. Kjøpt elektrisitet øker med 3 TWh fra 2020 til 2050. Ultra grønn-scenarioet viser at samlet levert energi reduseres med 13 TWh (15 %) fra 2020 til 2030 og med 40 TWh (48 %) fra 2020 til 2050. I samme perioder reduseres kjøpt elektrisitet med henholdsvis 13 TWh (19 %) og 42 TWh (60 %). Reduksjonen er et resultat av svært ambisiøse tiltak som fører til betydelig bedring i gjennomsnittlig energinivå, bruk av best tilgjengelig oppvarmingsteknologi, reduk-sjon i el-spesifikt energibehov og maksimal bruk av solstrøm. Solstrømsproduksjonen er på 4 TWh i 2030 og 12,5 TWh i 2050. Scenarioet antar optimal bruk av smarte styringssystemer, slik at i 2050 er 10 TWh av solstrømmen egenbruk og 2,5 TWh blir eksportert ut på nettet (beregnet på timebasis). Ultra grønn-scenarioet viser at det er et stort og viktig potensial for energisparing i bygningsmassen. Forskjellen mellom de to scenarioene viser imidlertid at potensialet ikke vil utløses ved en fortsettelse av dagens trender. Det er behov for å innføre virkemidler for å styre utviklingen i ønsket retning slik at bygningsmassen kan avlaste energisystemet. Vi har definert tiltakspakker for energieffektivisering for både nybygg og eksisterende bygg, for ulike bygningskategorier. Disse tiltakspakkene er kostnadsestimert og lønnsomhetsvurdert, og basert på dette har vi vurdert hvor mye støtte som må til for at tiltakene blir gjennomført. For definerte tiltaksnivåer for både nybygg og eksisterende bygg er det forutsatt teknologinøytralitet. Det vil si at nivåene kan nås med ulike kombinasjoner av passive tiltak på bygningskroppen (for eksempel isolasjon), tiltak når det gjelder tekniske installasjoner (for eksempel ventilasjon), termisk energiforsyning (for eksempel varmepumper) og lokal produsert strømproduksjon på bygget (for eksempel solceller). Det er beregnet at totale merkostnader for energitiltakene på både nye og eksisterende bygg for alle bygningskategorier vil ligge på ca. 18 milliarder NOK per år. Dette er fordelt med litt over 50 % på småhus og resten på leilighetsbygg og yrkesbygg. Videre har vi beregnet at for å få utløst potensialet i Ultra grønn-senarioet er det behov for støtte på 4–5 milliarder per år. Støttebeløpet kan trolig reduseres etter hvert som løsninger og teknologi blir bedre og mer kostnadseffektiv. Dette er betydelig mye mer enn det som gis i støtte til energieffektivisering i dag, men må ses i lys av alternativene vi har for å løse klimamålsetningene vi har satt og energi-underskuddet vi går mot. Vi foreslår ti tiltak og virkemidler for å utløse energisparepotensialet i eksisterende bygg og nybygg. De fem første vurderes som helt avgjørende for at potensialet som er beregnet skal utløses: • Klare mål som er langsiktige, konkrete, forpliktende og etterprøvbare, og som følges opp slik at tiltak og virkemidler kan justeres for å sikre at målene oppnås. • Tilskudd som dekker 30–35 % av beregnet merkostnad for ambisiøse tiltakspakker for nye og eksisterende bygg. • Grønne lån som finansierer de siste 2/3 av investeringene, særlig for de med liten til moderat investeringsevne. • Samordning av byggeforskrifter (TEK), energimerking (EMS) og Taksonomien slik at de bruker beregningspunktet levert energi eller tilsvarende, og at beregningene gjøres så realistiske at de kan sammenlignes med målt energibruk. • Trinnvis skjerping av krav i teknisk forskrift (TEK) hvert femte år. Vi har i denne rapporten også foreslått fem virkemidler som vi anbefaler at myndighetene utreder og vurderer på sikt: en egen forskrift ved rehabilitering av bygg (Rehab-TEK), energiforpliktelser for nettselskapene, netto tariff for bygg med eksport av solstrøm, nasjonalt og regionalt måleverktøy for energieffektivisering i bygningsmassen og nabodeling av elektrisk energi i energinabolag. Frigjøringen av energi og elektrisitet som beregnet i denne rapporten vil føre til langt mindre inngrep i naturen, redusere behovet for nettutbygging betydelig og være en tilnærmet konfliktfri løsning sammen-liknet med mange av alternativene. Dette vil også gjøre at den enkelte boligeier og byggherre kan bidra til å løse klima- og energiutfordringen samtidig som de gjør byggene sine mer energirobuste og øker byggenes verdi.publishedVersio

    Estudio geológico preliminar del complejo volcánico nevado Coropuna

    Get PDF
    El Complejo Volcánico Nevado Coropuna (CVNC) está ubicado en el extremo norte de la Zona Volcánica de los Andes Centrales (15 ° 3 ‘S, 72º39 ‘O), incluye varios edificios alineados en dirección ONO-ESE y emplazados sobre ignimbritas del Neogeno (13-2 Ma). Adyacente al CVNC se tienen dos volcanes, el estratovolcán Sunjillpa del Plioceno tardío en su extremo occidental, y el estratovolcán Cuncaicha de hace 0,6 -0,25 Ma, en su extremo oriental. El CVNC es típicamente asimétrico, está en el borde de la Cordillera Occidental y está conformado principalmente por flujos de lava, domos, domo « cluster » y domo-coladas. Los flujos de lava de corto recorrido, normalmente de menos de 7 km, cubren la meseta NE, N y NO, pero flujos de lava de mayor recorrido, entre 10 y 16 km, se han emplazados en los valles profundos ubicados al sur. También en la zona sur se han dentificado importantes depósitos de avalanchas de escombros, rellenando valles profundos a más de 20 km de distancia. En la parte central y más alta del CVNC se han identifi cado al menos 05 “clusters” de domos, de este a oeste, son el Yanaranra (6305 msnm), Coropuna (6160 msnm), Paiche (6330 msnm), Casulla (6377 msnm) y Escalera (6171 msnm). Recientes dataciones obtenidas en el marco de este proyecto arrojaron edades alrededor de 0.4 Ma para lavas ubicadas en la base, las cuales están cubiertas por lavas con edades entre 270-254 ka. En la parte media se han datado lavas entre 118-108 ka, y en la parte superior de los “clusters” de domos se han obtenido edades entre 70 - 60 ka. En base a un modelo de elevación digital (DEM) de 3 m de resolución, se han identifi cado al menos 6 centro de emisión, 5 domos « cluster », una escarpa de colapso principal abierta en dirección sur. Las lavas son andesitas y dacitas, con concentraciones de SiO2 que varían entre 57 a 67 % wt. Todas presentan alto contenido de K. Los diagramas de Harker sugieren un importante proceso de diferenciación magmática, así como procesos de AFC
    corecore